EXPORT
TO ALL COUNTRIES!
Contact Us:
sales@licht-labs.com.
MFC-300/R Voltage Regulator
- 8 parameter sets associated with daily time intervals
- Reference voltage: 80-140V - Bandwidth: 0-10% - Constant or inverse timer: 0-180s - Line drop compensation Vr, Vx: ±0-25V - Undervoltage blocking (with relay): 10-99% - Overvoltage blocking (with relay): 101-199% - Overcurrent blocking (with relay): 10-199% - Programmable current loop outputs - RS485 or Ethernet interface - MODBUS, DNP3 or IEC61850 protocol support - Full pairwise galvanic isolation - Panel mounted MFC-201/R Voltage Regulator
- 8 parameter sets associated with daily time intervals
- Reference voltage: 80-140V - Bandwidth: 0-10% - Constant or inverse timer: 0-180s - Line drop compensation Vr, Vx: ±0-25V - Undervoltage blocking (with relay): 10-99% - Overvoltage blocking (with relay): 101-199% - Overcurrent blocking (with relay): 10-199% - Programmable current loop outputs - RS485 interface - MODBUS or DNP3 protocol support - Full pairwise galvanic isolation - 35 mm DIN rail assembly MFC-202/P Parallelism Controller
- 80-265V universal power supply
- Supports up to 16 transformers - Master-Follower synchronous control - Current loop output for position retransmission - RS485 interface - MODBUS or DNP3 protocol support - Full pairwise galvanic isolation - 35 mm DIN rail installation |
MFC-300/T Temperature Controller
- 80-265V universal power supply
- 4 inputs: oil and 3 windings - Optional redundant RTD measurement - 14 programmable relays (setpoint, hysteresis, timeout) - 4 current loop outputs - RS485 or Ethernet interface - MODBUS, DNP3 or IEC61850 protocol support - Full pairwise galvanic isolation - Panel mounted MFC-300/T-Dry Temperature Controller
- Version for dry transformers and motors
- 80-265V universal power supply - Up to 6 RTD inputs - Up to 6 current loop outputs - Fan, alarm, trip and fault relays - RS485 interface - MODBUS or DNP3 protocol support - Full pairwise galvanic isolation - Panel mounted MFC-301/T-Dry Temperature Controller
- Version for dry transformers and motors
- 80-265V universal power supply - Up to 6 RTD inputs - 1 optional current loop output - Fan, alarm, trip and fault relays - RS485 interface - MODBUS or DNP3 protocol support - Full pairwise galvanic isolation - Panel mounted - Compact version of the MFC-300/T-Dry MFC-300/N Level Monitor
- 80-265V universal power supply
- up to 6 level inputs - 12 programmable relays (setpoint, hysteresis, timeout) - up to 6 current loop outputs - RS485 interface - MODBUS or DNP3 protocol support - Full pairwise galvanic isolation - Panel mounted |
DL/I Transducer/Indicator
- Transducer, indicator and transducer+indicator versions
- 80-265V universal power supply - 22 mm tall DIN enclosure - 35 mm DIN rail mounted - Possible inputs: - RTD (e.g.: Pt-100) - Thermocouple - DC current - AC current - DC voltage - AC voltage - Frequency - Position, universal sensor (SU) - Position, decadic sensor (Pos) - Possible outputs: - Voltage (e.g.: 0-10 V) - Current (e.g.: 4-20 mA) - Indicator: - 7 segment high brightness LED displays - Resolution: ± 1999 (3 ½ digits) MFC-300/I Transducer/Indicator
- 80-265V universal power supply
- up to 6 inputs - up to 6 current loop outputs - Possible inputs: - RTD (e.g.: Pt-100) - Thermocouple - DC current - AC current - DC voltage - AC voltage - Frequency - Position - RS485 interface - MODBUS or DNP3 protocol support - Full pairwise galvanic isolation - Panel mounted |
TD200 Transducer/Indicator
- Indicator and indicator+transducer versions
- 80-265V universal power supply - DIN 96x96, 96x48, 72x144 or 144x144 enclosure - Panel mounted - Possible inputs: - RTD (e.g.: Pt-100) - Thermocouple - DC current - AC current - DC voltage - AC voltage - Frequency - Position, universal sensor (SU) - Position, decadic sensor (Pos) - Possible outputs: - Voltage (e.g.: 0-10 V) - Current (e.g.: 4-20 mA) - Indicator: - 7 segment high brightness LED displays - Resolution: ± 1999 (3 ½ digits) TD100 Position Indicator
- 80-265V universal power supply
- BCD (8421) input - Resolution: 199 (2 ½ digits) - 7 segment high brightness LED displays - Multiplier relays for BCD remote commands - Full galvanic isolation Analog Indicator
- DIN 96x96, 96x48, 72x144 or 144x144 enclosure
- Possible inputs: - DC current - AC current - DC voltage - AC voltage |
BCD (8421)/mA Converter
- 80-265V universal power supply
- For reading tap changer positions - Full galvanic isolation MFC-300 mA/BCD Converter
- 80-265V universal power supply
- MODBUS or DNP3 interface - Full galvanic isolation BCD (8421 or Gray) Repeater
- 80-265V universal power supply
- Galvanically isolates and repeats BCD signals with relays |
Decimal/BCD (8421 or Gray) Encoder
- Diode matrix encoder
- 1 kV reverse voltage - 1 A maximum forward current MFC-201 mA/BCD Converter
- 80-265V universal power supply
- MODBUS or DNP3 interface - Full galvanic isolation |
BS-02 Bistable Relay
- 80-265V universal power supply
- 2.0 kV isolation - Models triggered by: - AC or DC voltage step - AC or DC voltage setpoint - AC or DC current setpoint - dry contact Oil Temperature Detector
- RTD detection
|
1x4 – 2.5 ms Fast Relay
- Auxiliary contact multiplier relay
- 4 SPDT contacts - Operation time ≤ 2.5 ms |